Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.883
Filtrar
1.
Sci Rep ; 11(1): 22963, 2021 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-34824361

RESUMO

Needle artifacts pose a major limitation for MRI-guided interventions, as they impact the visually perceived needle size and needle-to-target-distance. The objective of this agar liver phantom study was to establish an experimental basis to understand and reduce needle artifact formation during MRI-guided abdominal interventions. Using a vendor-specific prototype fluoroscopic T1-weighted gradient echo sequence with real-time multiplanar acquisition at 1.5 T, the influence of 6 parameters (flip angle, bandwidth, matrix, slice thickness, read-out direction, intervention angle relative to B0) on artifact formation of 4 different coaxial MR-compatible coaxial needles (Nitinol, 16G-22G) was investigated. As one parameter was modified, the others remained constant. For each individual parameter variation, 2 independent and blinded readers rated artifact diameters at 2 predefined positions (15 mm distance from the perceived needle tip and at 50% of the needle length). Differences between the experimental subgroups were assessed by Bonferroni-corrected non-parametric tests. Correlations between continuous variables were expressed by the Bravais-Pearson coefficient and interrater reliability was quantified using the intraclass classification coefficient. Needle artifact size increased gradually with increasing flip angles (p = 0.002) as well as increasing intervention angles (p < 0.001). Artifact diameters differed significantly between the chosen matrix sizes (p = 0.002) while modifying bandwidth, readout direction, and slice thickness showed no significant differences. Interrater reliability was high (intraclass correlation coefficient 0.776-0.910). To minimize needle artifacts in MRI-guided abdominal interventions while maintaining optimal visibility of the coaxial needle, we suggest medium-range flip angles and low intervention angles relative to B0.


Assuntos
Abdome/diagnóstico por imagem , Biópsia por Agulha , Imagem por Ressonância Magnética Intervencionista/métodos , Agulhas , Imagens de Fantasmas , Artefatos , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Humanos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes
2.
Ann Hepatol ; 26: 100548, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34600141

RESUMO

INTRODUCTION AND OBJECTIVES: Assessment of liver biopsy sample adequacy criteria is essential to avoid sampling errors in patients with diffuse liver pathology. Many studies have evaluated these criteria in adults; however, no previous studies have been performed on neonatal liver disorders. We aimed to assess the adequacy criteria of Tru-cut needle liver biopsy samples in infants with neonatal cholestasis (NC). METHODS: In a retrospective analysis of infants who underwent liver biopsy for NC within a one-year duration, 58 specimens were recruited. The core lengths after fixation were measured. All samples were acquired with a 16-gauge (G) Tru-cut needle. Serial shortening of these samples was performed to define the smallest core length that gives representative parenchyma that could determine the activity grade and fibrosis stage reported by larger cores. RESULTS: It was found that a 4-mm core length with a complete portal tract (CPT) number of 8±3 could adequately assess the NC activity grade. In addition, a 6-mm core length with a CPT number of 11±3 could adequately estimate NC fibrosis stage. CONCLUSIONS: The adequacy criteria of liver tissue samples for the accurate assessment of NC are different from those defined for adult diffuse liver pathology. At least a 4-mm core length with a CPT number of 8±3 and a 6-mm core length with a CPT number of 11±3 acquired by a 16-G Tru-cut needle should be used to assess NC activity grade and fibrosis stage, respectively.


Assuntos
Biópsia por Agulha/instrumentação , Colestase/diagnóstico , Fígado/patologia , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
4.
Br J Radiol ; 94(1125): 20210475, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34289324

RESUMO

OBJECTIVES: To determine biopsy device failures, causative factors, complications and sample quality of the 16G end-cut Biopince™ and side-notch Bard™ needles. METHODS: All ultrasound-guided non-targeted liver biopsies between 01/01/2016 and 31/12/2018 were included. Operator, device, number of failures, complications and repeat biopsies were recorded. Histopathology samples were reviewed for all cases of needle failure and a group with no failures, and graded "yes/no" for the presence of steatosis, inflammation and fibrosis. The pathology slides from these cases were reviewed to assess biopsy sample quality (length and portal tract number). The failure and no-failure groups were compared in terms of device type/histology, and sample quality was compared between the needle types. RESULTS: 1004 patients were included. 93.8% (n = 942) required one needle pass to obtain a sample and 6.2% (n = 62) required >1 pass due to needle failure. Total of 76 needle failures, more with end-cut than side-notch needles (8.7% vs 2.9%) (p < 0.001). No needle failures resulted in complication. The presence of liver fibrosis was associated with fewer needle failures (p = 0.036). The major complication rate was 0.4% (4/1044). A biopsy with >10 portal tracts was obtained in 90.2% of specimens > 20 mm long, compared with 66% of 16-20 mm biopsies and 21% of <16 mm biopsies. The target of >10 portal tracts was achieved in 10/26 (38.5%) of side-notch biopsies and 64/90 (71.1%) of end-cut biopsies (p = 0.004). CONCLUSION: Ultrasound-guided liver biopsy is safe and sample quality is consistently good when a core >20 mm long is obtained. The end-cut biopsy device generated reliably good quality biopsy samples; however, the needle failure rate was significantly higher than the side-cut needle. ADVANCES IN KNOWLEDGE: Ultrasound-guided liver biopsy specimen quality is consistently good when a core >20 mm long is obtained which can be achieved with a single pass using the 16G BiopinceTM end-cut needle, although the needle failure rate is significantly higher than the 16G Max-Core™ Bard™ side-notch needle.


Assuntos
Falha de Equipamento/estatística & dados numéricos , Fígado/patologia , Ultrassonografia de Intervenção/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Desenho de Equipamento , Feminino , Humanos , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/métodos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
5.
Prostate Cancer Prostatic Dis ; 24(2): 431-438, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32999465

RESUMO

BACKGROUND: To investigate the feasibility of a freehand transperineal (TP) systematic prostate biopsy protocol under local anaesthesia (LA) and the value of different sectors in diagnosing prostate cancer (PCa). METHODS: A total of 611 consecutive freehand TP biopsies under LA in 2 hospitals were prospectively evaluated. Cancer detection rate in each of the four different sectors (anterior, mid, posterior, basal) was recorded to evaluate the value of each sector. Procedure tolerability was assessed by pain score and complications were documented. RESULTS: Systematic biopsies were performed in 556 out of 611 men with a median of 20 (IQR 12-24) biopsy cores taken. The median PSA was 9.9 (Inter-quartile range[IQR] 6.4-16.2) ng/mL, and 89.0% were first biopsies. All PCa and ISUP grade group (GG) ≥ 2 PCa (HGPCa) were diagnosed in 41.4% (230/556) and 28.2% (157/556) biopsies respectively. 77.0% HGPCa was diagnosed in ≥2 sectors. Single-sector HGPCa was predominantly found in anterior or posterior sector. Omitting base sector would have missed 1.5% (1/65) HGPCa out of the 219 cases with ≥24-core biopsies performed. Further omission of mid sector would have missed 3.1% (2/65) HGPCa and 7.4% (7/94) ISUP GG1 PCa (in which 3/7 involved 2 sectors). LA TP biopsy was well tolerated and the mean pain scores of the different steps of the procedure were between 1.9-3.1 (out of 10). Post-biopsy fever occurred in 0.3% of patients (2/611) and no sepsis was reported. The risk of urinary retention in men with ≥20 cores in ≥60 ml prostate was 7.8% (14/179), compared with 1.7% (7/423) in other groups (p < 0.001). CONCLUSIONS: TP sectoral prostate biopsy under LA was well tolerated with minimal sepsis risk. Basal sector biopsies had minimal additional value to HGPCa detection and its omission can be considered.


Assuntos
Anestesia Local/métodos , Biópsia por Agulha/instrumentação , Períneo/patologia , Próstata/patologia , Neoplasias da Próstata/patologia , Idoso , Estudos de Viabilidade , Seguimentos , Humanos , Biópsia Guiada por Imagem , Masculino , Pessoa de Meia-Idade , Períneo/cirurgia , Prognóstico , Estudos Prospectivos , Próstata/cirurgia , Neoplasias da Próstata/cirurgia
6.
Auris Nasus Larynx ; 48(2): 281-287, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33288360

RESUMO

OBJECTIVES: The cause of cervical lymphadenopathy varies from inflammation to malignancy. Accurate and prompt diagnosis is crucial as delayed detection of malignant lymph node can lead to a worse prognosis. To improve the diagnostic accuracy of metastatic lymph node, electrical spectroscopy was employed to study human normal and metastatic lymph nodes using a hypodermic needle with fine interdigitated electrodes on its tip (EoN). SUBJECTS AND METHODS: The electrical impedance of samples collected from 8 patients were analyzed in the sweeping frequency range from 1 Hz to 1 MHz. To align the impedance level data of the patients, normalized impedance was employed. RESULTS: The optimal frequency exhibiting the best discrimination results between the normal and cancerous tissues was introduced based on a discrimination index. A high sensitivity (86.2%) and specificity (88.9%) were obtained, which implied that the EoN holds the potential to improve the in vivo diagnostic accuracy of metastatic lymph node during biopsy and surgery. CONCLUSION: EoN has a promising potential to be utilized in real-time in actual clinical trials without a need for any pre/post-treatment during FNA or surgery. We believe that the EoN could reduce unnecessary operations with its associated morbidity.


Assuntos
Biópsia por Agulha/instrumentação , Espectroscopia Dielétrica , Eletrodos , Linfonodos/patologia , Metástase Linfática/diagnóstico , Biópsia por Agulha/métodos , Humanos , Metástase Linfática/patologia , Valores de Referência , Sensibilidade e Especificidade
7.
Sci Rep ; 10(1): 17098, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33051506

RESUMO

We developed a novel dividing device that can split needle biopsy tissues along longitude axis aiming to achieve definitive molecular-biological and genetical analysis with reference of pathological diagnosis of the side-by-side divided tissue as spatially matched information. The aim of this study was to evaluate the feasibility and potential usefulness of the novel dividing device to provide the appropriate materials for molecular diagnosis. The new device was examined using mouse xenograft tumors. Real-time quantitative PCR and genetic test were performed to evaluate the feasibility and usefulness of the device. All the samples from needle biopsy were successfully divided into two pieces. Quality and quantity from divided samples harbor high enough to perform gene expression analysis (real-time PCR) and genetic test. Using two divided samples obtained from xenograft tumor model by needle biopsy, the % length of xenograft tumor (human origin) was significantly correlated with the % human genomic DNA (p = 0.00000608, r = 0.987), indicating that these divided samples were spatially matched. The novel longitudinally dividing device of a needle biopsy tissue was useful to provide the appropriate materials for molecular-biological and genetical analysis with reference of pathological diagnosis as spatially matched information.


Assuntos
Biópsia por Agulha/instrumentação , Neoplasias Experimentais/patologia , Manejo de Espécimes/instrumentação , Animais , Biópsia por Agulha/métodos , Linhagem Celular Tumoral , Estudos de Viabilidade , Testes Genéticos , Humanos , Camundongos , Camundongos SCID , Transplante de Neoplasias , Neoplasias Experimentais/cirurgia , Reação em Cadeia da Polimerase em Tempo Real , Manejo de Espécimes/métodos
8.
Eur J Radiol ; 131: 109237, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32905954

RESUMO

PURPOSE: To evaluate the surgical upgrade rate to malignancy and high-risk lesions in cases of papilloma without atypia diagnosed with imaging-guided percutaneous core needle biopsy (CNB) and to determine whether any lesion imaging features, biopsy techniques, and pathological factors can predict lesion upgrade to help guide clinical management. MATERIALS AND METHODS: Benign papillomas without atypia (n = 399) diagnosed with CNB were retrospectively reviewed. The surgical upgrade rate to malignancy or high-risk lesion (atypical ductal hyperplasia, atypical lobular hyperplasia, lobular carcinoma in-situ, flat epithelial atypia and atypical papilloma) was determined. Detection modality (i.e. mammography, ultrasonography (US), magnetic resonance imaging (MRI)), lesion type and size, biopsy-guidance modality (US, stereotactic, MRI), biopsy needle size (<14 G vs ≥14 G), use of vacuum assistance, and presenting symptoms were statistically analyzed. The reference standard for evaluation of upgrade was either excision or at least 24 months of imaging follow-up. Chi Square test and Fisher exact tests were performed for categorical variables, and the Mann-Whitney-U test was used for continuous variables. RESULTS: Ultrasound was the predominant biopsy modality (78.4 %, p < 0.001). Of the 399 benign papilloma lesions in 329 women, 239 (59.9 %) were excised and 93 others were followed for at least 24 months (total of 332). Of these 332 lesions, 7 (2.1 %) were upgraded to ductal carcinoma in-situ and 41 (12.3 %) to high-risk lesions at excision. Larger lesion size (≥15 mm, p = 0.009), smaller biopsy needle size (≥14 G, p = 0.027), and use of spring-loaded biopsy device (p = 0.012) were significantly associated with upgrade to atypia. Only lesion size (≥15 mm, p = 0.02) was associated with upgrade to cancer. CONCLUSION: Upgrade to malignancy of biopsy-proven benign papillomas without atypia at the time of surgery was sufficiently low (2.1 %) to support non-operative management. Surgery may be performed for selected cases- those with larger lesion size and those whose biopsies were performed with smaller spring-loaded biopsy needles.


Assuntos
Biópsia por Agulha , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Biópsia Guiada por Imagem , Papiloma/diagnóstico por imagem , Papiloma/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Intraductal não Infiltrante/cirurgia , Distribuição de Qui-Quadrado , Feminino , Seguimentos , Humanos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética , Mamografia , Pessoa de Meia-Idade , Papiloma/patologia , Estudos Retrospectivos , Estatísticas não Paramétricas , Ultrassonografia Mamária
9.
Urol J ; 18(3): 307-313, 2020 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-32869256

RESUMO

PURPOSE: To investigate biopsy needle tip culture after prostate biopsies for bacteria prediction and antibiotics selection. MATERIALS AND METHODS: From May 2017 to April 2019, 121 patients who underwent a prostate biopsy were enrolled. All biopsy needle tips were sent for aerobic and anaerobic culture. Patients were divided into positive and negative culture groups. Perioperative data were recorded and compared between the two groups. The culture time and susceptibility of febrile patients were analyzed. Blood cultures were conducted for all patients who experienced fever after biopsy. The time and results of the needle and blood cultures were recoded for descriptive analysis. RESULTS: There were 59 (48.8%) positive needle cultures. Other than fever (p = 0.023), there were no statistical significances in clinical data between the two groups. Fever occurred in eight patients, and seven febrile patients had positive needle cultures, six of whom had positive blood cultures. These six needle and blood cultures were consistent with the susceptibility test results. As compared to the waiting time for blood cultures, target antibiotics were administered at an average of 48.0 h earlier based on needle cultures. None of the patients with positive anaerobic cultures developed a fever, while all eight febrile patients had negative anaerobic cultures. CONCLUSION: Fevers developed at statistically significant higher rate among those who had positive needle cultures. Needle and blood cultures were consistent with the susceptibility test results. Needle cultures can help us administer target antibiotics earlier to febrile patients without the need to wait for blood cultures.


Assuntos
Antibacterianos/uso terapêutico , Infecções Bacterianas/prevenção & controle , Agulhas/microbiologia , Complicações Pós-Operatórias/microbiologia , Complicações Pós-Operatórias/prevenção & controle , Próstata/patologia , Idoso , Biópsia por Agulha/instrumentação , Diagnóstico Precoce , Humanos , Masculino , Pessoa de Meia-Idade
10.
Sci Rep ; 10(1): 14200, 2020 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-32848190

RESUMO

This paper presents the results of the experiments which were performed using the optical biopsy system specially developed for in vivo tissue classification during the percutaneous needle biopsy (PNB) of the liver. The proposed system includes an optical probe of small diameter acceptable for use in the PNB of the liver. The results of the feasibility studies and actual tests on laboratory mice with inoculated hepatocellular carcinoma and in clinical conditions on patients with liver tumors are presented and discussed. Monte Carlo simulations were carried out to assess the diagnostic volume and to trace the sensing depth. Fluorescence and diffuse reflectance spectroscopy measurements were used to monitor metabolic and morphological changes in tissues. The tissue oxygen saturation was evaluated using a recently developed approach to neural network fitting of diffuse reflectance spectra. The Support Vector Machine Classification was applied to identify intact liver and tumor tissues. Analysis of the obtained results shows the high sensitivity and specificity of the proposed multimodal method. This approach allows to obtain information before the tissue sample is taken, which makes it possible to significantly reduce the number of false-negative biopsies.


Assuntos
Neoplasias Hepáticas/diagnóstico , Fígado/patologia , Ultrassonografia de Intervenção/instrumentação , Idoso , Animais , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Estudos de Viabilidade , Feminino , Humanos , Aprendizado de Máquina , Masculino , Camundongos , Pessoa de Meia-Idade , Projetos Piloto , Ultrassonografia de Intervenção/métodos
11.
BMC Nephrol ; 21(1): 337, 2020 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-32787784

RESUMO

BACKGROUND: Percutaneous renal biopsy (PRB) is the primary biopsy technique and it was used by 16G needles or 18G needles in China, but there is controversy about the effect and safety of the two different diameters. The study aims to compare the adequacy, complication rate and pathological classification when using 18G vs. 16G needles to perform renal biopsy with ultrasound-guidedance on native kidneys in Chinese individuals. METHODS: We retrospectively analyzed the number of glomeruli, adequate sample rates, complication rates and pathological classification in 270 patients with the use of 18G or 16G needles from January 2011 to May 2017 and verified whether the needle gauge affected the disease diagnosis. RESULTS: A total of 270 kidney biopsies were performed. Among them,72 were performed with 18G needles, and 198 were performed with 16G needles. There was no difference in the number of glomeruli under light microscope using 18G relative to 16G needles (24 ± 11 vs. 25 ± 11, p = 0.265), whereas more glomeruli were found in the 16G group than in the 16G group using immunofluorescence microscopy (3 ± 2 vs. 5 ± 3, p < 0.05). There was no significant difference in the adequate sample rates between the 18G group and the 16G group (90.28% vs. 93.94%, p = 0.298). Minor complications including the incidence of lumbar or abdominal pain (4.17% vs. 7.07%, p = 0.57), gross hematuria (4.17% vs. 3.54%, p = 0.729), and perinephric hematoma without symptoms (4.17% vs. 1.52%, p = 0.195), were not significantly different between the 18G and 16G groups. In the 16G group, 2 cases of serious complications occurred: severe gross hematuria requiring blood transfusion and retroperitoneal hematoma requiring surgery. No serious complications were observed in the 18G group, although there was no significant difference in serious complications rates between the 18G and 16G groups (0% vs. 1.02%, p = 1). CONCLUSION: There was no significant difference in the number of glomeruli, adequate sample rates, or complication rates when using 18G or 16G needles to perform renal biopsy, and the use of an 18G needle with a smaller diameter did not affect the pathological diagnosis or classification of IgA nephropathy and lupus nephritis.


Assuntos
Dor Abdominal , Anemia , Biópsia por Agulha , Hematoma , Hematúria , Rim , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Dor Abdominal/epidemiologia , Anemia/epidemiologia , Anemia/etiologia , Anemia/terapia , Transfusão de Sangue/estatística & dados numéricos , China/epidemiologia , Embolização Terapêutica/estatística & dados numéricos , Hematoma/epidemiologia , Hematoma/etiologia , Hematúria/epidemiologia , Hematúria/terapia , Rim/patologia , Glomérulos Renais/patologia , Agulhas , Espaço Retroperitoneal , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/instrumentação
13.
PLoS One ; 15(7): e0236295, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32706813

RESUMO

The purpose of the present study was to integrate an interactive gradient-based needle navigation system and to evaluate the feasibility and accuracy of the system for real-time MR guided needle puncture in a multi-ring phantom and in vivo in a porcine model. The gradient-based navigation system was implemented in a 1.5T MRI. An interactive multi-slice real-time sequence was modified to provide the excitation gradients used by two sets of three orthogonal pick-up coils integrated into a needle holder. Position and orientation of the needle holder were determined and the trajectory was superimposed on pre-acquired MR images. A gel phantom with embedded ring targets was used to evaluate accuracy using 3D distance from needle tip to target. Six punctures were performed in animals to evaluate feasibility, time, overall error (target to needle tip) and system error (needle tip to the guidance needle trajectory) in vivo. In the phantom experiments, the overall error was 6.2±2.9 mm (mean±SD) and 4.4±1.3 mm, respectively. In the porcine model, the setup time ranged from 176 to 204 seconds, the average needle insertion time was 96.3±40.5 seconds (min: 42 seconds; max: 154 seconds). The overall error and the system error was 8.8±7.8 mm (min: 0.8 mm; max: 20.0 mm) and 3.3±1.4 mm (min: 1.8 mm; max: 5.2 mm), respectively.


Assuntos
Biópsia por Agulha , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Punções , Animais , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Agulhas , Imagens de Fantasmas , Punções/instrumentação , Punções/métodos , Suínos
14.
Eur Radiol ; 30(11): 5964-5970, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32518988

RESUMO

OBJECTIVES: To evaluate the efficacy and safety of performing a fluoroscopically guided bone marrow aspiration and biopsy (BMAB) using a drill-powered needle in a large patient population. METHODS: This retrospective study received institutional review board approval with a waiver of patient informed consent. We identified all BMAB procedures from August 2012 through December 2016 performed at our institution using fluoroscopic guidance and a drill-powered needle. Clinical diagnosis, patient age, patient gender, biopsy site, biopsy needle gauge, bone marrow aspirate volume, bone marrow core biopsy length, patient platelet count, conscious sedation details, complications, and diagnostic adequacy were investigated for each case and summarized. RESULTS: A total of 775 BMAB procedures were performed and analyzed. These were performed in 436 female patients and 339 male patients ranging in age between 16 and 91 years (average age of 53 years). Samples obtained from the procedures in our series were diagnostic in 95.0% of cases. The complication rate for our series was 0.3%. CONCLUSIONS: The use of fluoroscopic guidance and a drill-powered needle for bone marrow aspiration and biopsy is a safe and efficacious procedure. KEY POINTS: • Fluoroscopy can be utilized for imaging guidance during bone marrow aspiration and biopsy. • The use of fluoroscopic guidance and a drill-powered needle for bone marrow aspiration and biopsy has a high diagnostic yield. • The procedure has an excellent patient safety profile.


Assuntos
Biópsia por Agulha/instrumentação , Medula Óssea/patologia , Fluoroscopia/métodos , Biópsia Guiada por Imagem/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
15.
Jpn J Radiol ; 38(6): 579-586, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32124166

RESUMO

PURPOSE: To assess specimen weight difference of six types of semi-automatic cutting biopsy needles. MATERIALS AND METHODS: We compared 18- and 20-gauge needles, one aspiration-type (STARCUT® aspiration-type, TSK Laboratory, Tochigi, Japan) and five non-aspiration-type (MISSION®, BARD, AZ; SuperCore™, Argon Medical Devices, TX; Temno Evolution®, Care Fusion, IL; FINE CORE®, Toray Medical, Tokyo, Japan; Quick-Core®, Cook, IN) needles. Four biopsies were performed with each needle with the longest throw length on an excised bovine liver. The biopsies were repeated with new needles, four times with four different livers. STARCUT® was used both with and without aspiration. RESULTS: Sixteen specimens were obtained with each needle. In needles of gauges, STARCUT® with aspiration provided the heaviest specimen and significantly heavier specimens were obtained with STARCUT® with aspiration (P < 0.05) than five non-aspiration-type needles. The specimen weight differed significantly (P < 0.001) among all 18- and 20-gauge needles. The specimen weights did not differ significantly between aspiration and non-aspiration biopsies with STARCUT® (6.32 vs. 5.97 mg with 18-gauge needle, P = 0.342; 1.95 vs. 1.92 mg with 20-gauge needle, P = 0.886). CONCLUSION: Although STARCUT® with aspiration provided the heaviest specimen, specimen weights were not significantly different between aspiration and non-aspiration biopsies. We assessed the specimen weight difference of six types of semi-automatic cutting biopsy needles. Significantly heavier specimens were obtained with STARCUT® with aspiration than the other needles. The specimen weight differed significantly among all 18- and 20-gauge needles but did not differ significantly between aspiration and non-aspiration biopsies with STARCUT®.


Assuntos
Fígado/patologia , Manejo de Espécimes/instrumentação , Animais , Biópsia por Agulha/instrumentação , Bovinos , Desenho de Equipamento , Feminino , Humanos , Masculino , Modelos Animais
17.
Artigo em Inglês | MEDLINE | ID: mdl-32117052

RESUMO

The current gold standard for the diagnosis of osteoporosis and the prediction of fracture risk is the measurement of bone mineral density (BMD) using dual energy x-ray absorptiometry (DXA). A low BMD is clearly associated with increased fracture risk, but BMD is not the only determinant of bone strength, particularly in secondary osteoporosis and metabolic bone disorders in which components other than BMD are affected and DXA often underestimates true fracture risk. Material properties of bone which significantly contribute to bone strength have become evaluable in vivo with the impact microindentation (IMI) technique using the OsteoProbe® device. The question arises whether this new tool is of added value in the evaluation of bone fragility. To this effect, we conducted a systematic review of all clinical studies using IMI in vivo in humans also addressing practical aspects of the technique and differences in study design, which may impact outcome. Search data generated 38 studies showing that IMI can identify patients with primary osteoporosis and fractures, patients with secondary osteoporosis due to various underlying systemic disorders, and scarce longitudinal data also show that this tool can detect changes in bone material strength index (BMSi), following bone-modifying therapy including use of corticosteroids. However, this main outcome parameter was not always concordant between studies. This systematic review also identified a number of factors that impact on BMSi outcome. These include subject- and disease-related factors such as the relationship between BMSi and age, geographical region and the presence of fractures, and technique- and operator-related factors. Taken together, findings from this systematic review confirm the added value of IMI for the evaluation and follow-up of elements of bone fragility, particularly in secondary osteoporosis. Notwithstanding, the high variability of BMSi outcome between studies calls for age-dependent reference values, and for the harmonization of study protocols. Prospective multicenter trials using standard operating procedures are required to establish the value of IMI in the prediction of future fracture risk, before this technique is introduced in routine clinical practice.


Assuntos
Osso e Ossos/patologia , Equipamentos e Provisões , Fraturas Ósseas/diagnóstico , Microtecnologia , Manejo de Espécimes , Absorciometria de Fóton , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Densidade Óssea , Doenças Ósseas Metabólicas/diagnóstico , Doenças Ósseas Metabólicas/patologia , Fraturas Ósseas/patologia , Humanos , Microtecnologia/instrumentação , Microtecnologia/métodos , Osteoporose/diagnóstico , Osteoporose/patologia , Fraturas por Osteoporose/diagnóstico , Fraturas por Osteoporose/patologia , Valor Preditivo dos Testes , Fatores de Risco , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos
18.
Niger J Clin Pract ; 23(2): 246-251, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32031101

RESUMO

AIMS: This study aims to discuss the relationship between complications and patient characteristics and lesion properties in the transthoracic fine needle aspiration biopsy (TTFNAB) procedures performed for lung lesions and the treatment applied in our clinic to eliminate these complications. METHODS: In this retrospective study conducted from July 2014 to August 2017, the CT-guided TTFNAB was performed on 186 patients (145 males, 41 females) who were considered to have malignancies on their clinical evaluation, CT, and PET CT results. RESULTS: After 186 CT-guided TTFNAB interventions, a total of 24 (12.9%) patients developed procedure-related pneumothorax. Of these patients, 7 had a limited and minimal pneumothorax and no treatment was required for them, while 17 had a large and increasing pneumothorax and manual air aspiration was performed with coaxial needle during the procedure. The number pleural transitions (OR 6.513; 95%, 2,529-16,771 P < 0.001), emphysematous lungs (OR 4.612; 95%, 1,852-11.487 P < 0.001), and the presence of a lesion unrelated to the pleura (OR 8.205; 95%, 3,162-21,291 P < 0.001) can form the basis for the development of a pneumothorax. CONCLUSION: The chances of developing pneumothorax after TTFNAB depend on number of pleural transition, emphysematous lungs, and non-pleural lesions. However, it is considered that procedures such as manual air aspiration and autologous blood patch may reduce the need for chest tube following the development of pneumothorax.


Assuntos
Biópsia por Agulha Fina/efeitos adversos , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/instrumentação , Pulmão/patologia , Pneumotórax/etiologia , Radiografia Intervencionista , Adulto , Idoso , Tubos Torácicos/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pneumotórax/terapia , Enfisema Pulmonar , Testes de Função Respiratória , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X/efeitos adversos
19.
J Clin Pathol ; 73(9): 552-556, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31919143

RESUMO

AIMS: The purpose of this report is to describe a new instrument designed for the injection of therapeutic agents directly into the bone marrow cavity as well as to aspirate bone marrow specimens for the diagnostic purposes. METHODS: The instrument consists of three parts: the needle, stilette and an adjustable guard. The overall length of the needle is 76 mm and has uniform external diameter except for the distal penetrating segment, which is sharp but short and safe to use on the sternum. The proximal end of the needle is fitted with a plastic T-bar handle, which is ergonomically designed for firm grip and easy manoeuvrability. RESULTS: The instrument has been designed to obtain bone marrow aspirate specimens as well as to inject therapeutic agents into the posterior ilium. CONCLUSIONS: The rationale for the intramedullary injection of therapeutic agents for the treatment of patients with leukaemia, lymphoma and other haematological and non-haematological malignant disorders is described. In an emergency when intravenous therapy becomes difficult due to collapsed veins, this instrument may be used for direct intramarrow infusion of blood and blood products.


Assuntos
Antineoplásicos/administração & dosagem , Injeções/instrumentação , Leucemia/tratamento farmacológico , Linfoma/tratamento farmacológico , Agulhas , Neoplasias/tratamento farmacológico , Biópsia por Agulha/instrumentação , Medula Óssea/patologia , Humanos , Ílio/patologia , Leucemia/diagnóstico , Leucemia/patologia , Linfoma/diagnóstico por imagem , Linfoma/patologia , Neoplasias/diagnóstico , Neoplasias/patologia
20.
J Vasc Access ; 21(1): 73-78, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31204556

RESUMO

BACKGROUND: Percutaneous renal biopsy can result in serious complications. The study is aimed to compare the safety and yield between the two approaches of biopsy techniques: the conventional craniocaudal and the caudocranial trajectory of the biopsy needle under real-time ultrasound guidance. METHODS: In this prospective observational study, a total of 80 serial kidney biopsies were performed, 40 with craniocaudal angulation and 40 with caudocranial angulation of the biopsy needle on the random allocation of 1:1 in each group. In the craniocaudal approach, the patient must hold the breath in deep inspiration to make a lower pole of the kidney approachable during unloading the biopsy gun, which was not required in caudocranial trajectory as the lower pole was approachable without holding the breath in deep inspiration. All kidney biopsies were performed percutaneously under real-time ultrasonogram guidance with a 16-cm-long, 16- or 18-gauge needles with a penetration depth of 22 mm and a sample notch of 18 mm. The yield and complications between the two groups were analyzed. RESULTS: Both the groups were comparable in essential demographic characteristics. The study found that the caudocranial position of renal biopsy is equally suitable concerning tissue yield without any increase in the risk of complications and a smaller number of passes to obtain adequate tissue. CONCLUSION: Caudocranial trajectory of the biopsy needle using a probe needle guide is as safe as the craniocaudal approach. Both approaches have similar yield and complications; however, the caudocranial approach provides ease to the patient during the procedure.


Assuntos
Biópsia por Agulha , Biópsia Guiada por Imagem/métodos , Nefropatias/patologia , Rim/patologia , Ultrassonografia de Intervenção , Adolescente , Adulto , Idoso , Biópsia por Agulha/instrumentação , Criança , Desenho de Equipamento , Feminino , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/instrumentação , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Agulhas , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...